| Demagnetizers |
| Demagnetizing coils are used for demagnetizing magnetite and ferrocilicon slurries to eliminate coagulation of strongly magnetic particles preventing size separation of particulate material |
| |
|
| Type | Pipe
dia.
mm | Pulp
flow
rate,
m3/h | Peak
flux
density
of
magnetic
field
in
active
zone
with
no
pulp
flow,
mT,
not less | Rated
AC
voltage,
V | Rated
AC
current
at 50Hz
with
no pulp
in,
A | AC power,
Active, W
—
Total, kVA
| Overall dimensions, mm
Length
—
Width
—
Height
| Mass,
kg |
AR-50
(178-SE) | 50 | 25 | 70 | 380 | 9,2 | 150
—
3,5 | 458
—
930
—
492 | 124 |
AR-75 (158-SE)
| 75 | 54 | 50 | 380 | 6,8 | 120
—
2,5 | 506
—
970
—
543
| 172 |
AR-100 (177-SE)
| 100 | 85 | 50 | 380 | 15,0 | 165
—
5,7 | 574
—
1050
—
608
| 266 |
AR-150 (223-SE)
| 150 | 150 | 60 | 220 | 42 | 480
—
9,2 | 500
—
750
—
500
| 120 |
AR-200 (176-SE)
| 200 | 300 | 50 | 380 | 28 | 230
—
10,6 | 635
—
1440
—
670
| 346 |
AR-450 (225-SE)
| 450 | 1500 | 44 | 380 | 200 | 1850
—
76 | 1600
—
980
—
990
| 500 |
|
 |
Order equipment

|
|
|